Flash & Batt Hybrid System

The Flash & Batt Hybrid system consists of a hybrid between closed cell spray foam (the flash) and fiberglass batt insulation (the batt). 1/2 inch of closed cell spray foam is applied to all the exterior sheathed wall cavities, then the rest of the cavity is filled with the appropriate thickness fiberglass batt. This method gives the best of both worlds, the air sealing and moisture management of closed cell foam, with the lower cost fiberglass batt for the additional R-value. The result is a high performance insulation system with a much lower construction cost than using all spray foam. While using all spray foam is the best option available, it comes with a much higher cost. The testing Home Pro Energy has preformed backs up the performance and cost effectiveness of the Flash & Batt system. See the previous page for other Hybrid options available from Toler Insulating.

The Flash & BIBS hybrid system is very similar to the Flash & Batt system and shares all the same benefits. It starts with a 1/2″ closed cell foam sprayed to all the exterior sheathed wall cavities, then is covered with the BIBS (blown in blanket) fiberglass system. The result is a higher additional R-value installed over the foam than with a standard Flash & Batt. The fiberglass BIBS system yields 4.2 R’s per inch additional R-value. Much like the Flash & Batt system the result is a high performance insulation system with a much lower construction cost than using all spray foam. While using all spray foam is the best option available, it comes with a much higher cost. The testing Home Pro Energy has preformed backs up the performance and cost effectiveness of the Flash & Batt system. See the previous page for other Hybrid options available from Toler Insulating.

The Flash and Foil hybrid system is similar to the other two hybrid systems in that it uses two different products in the wall cavity. It differs in the amount of foam applied and total R value achieved. The flash and foil hybrid system starts with 2" of closed cell foam sprayed to all exterior sheathed walls, then the wall cavity is covered with Hy-Fi high reflective, low emittance foil insulation. The result is an extremely high R-value in a small amount of space, and at a lower cost than using all foam. The flash and foil hybrid system can achieve R-21 in a standard 2x4 wall cavity and R-22 in 2x6 while only requiring 2" of closed cell foam. Give us a call or request a proposal to discuss all the insulation options available to you or to request a free evaluation of your current insulation levels.

177 Airpark Drive
Lynchburg, Virginia 24502

Office Phone: 434-239-8590
Office Fax: 434-239-0787
Main Office Contacts

President/Owner: Wayne Toler
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Accounting/Office Manager:
Katherine Pino
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Heidi Toler
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

After-Paint Products

Anders Sunwall
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.
Estimating department

Residential
Paul Newman – Vice President
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Brad Garnett
Email: This email address is being protected from spambots. You need JavaScript enabled to view it.

Commercial
Wayne Toler
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

General
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.